AeHIN Medical Certificate of Cause of Death (MCCoD) Implementation Guide - Published by Asia eHealth Information Network (AeHIN). See the Directory of published versions
This page records the change history of the AeHIN MCCoD Implementation Guide.
Changes are listed in reverse chronological order. The version numbering follows
Semantic Versioning (SemVer):
MAJOR.MINOR.PATCH.
Version 0.1.0 — 2026-05-21
Status: Draft for AeHIN Member Review
Publication: Hosted at
http://mccod.w3datanet.com/fhir
(temporary draft URL; AeHIN will assign official canonical before formal publication)
Initial draft release. This is the first version of the AeHIN MCCoD IG, produced
for review and feedback by AeHIN member countries. All artifacts are at
maturity level 0 (draft). No ballot or formal publication has occurred.
Profiles
-
MCCoDComposition —
Top-level document Composition with Frame A (mandatory) and Frame B (optional)
sections. Includes 9 cross-resource invariants (5 error, 4 warning).
-
MCCoDCauseOfDeathCondition —
Condition profile for causal chain entries (lines a–d) with mandatory
linePosition extension.
-
MCCoDUnderlyingCauseOfDeath —
Separate mandatory Condition profile for the underlying cause of death, with
mandatory
dorisDerived extension supporting ICD-11/DORIS workflows.
-
MCCoDContributingCondition —
Condition profile for Frame A Part 2 contributing conditions.
-
MCCoDMannerOfDeath —
Observation profile for manner of death (LOINC 69449-7).
-
MCCoDAutopsyPerformed —
Observation profile for autopsy requested and findings used (LOINC 85699-7).
-
MCCoDSurgeryPerformed —
Observation profile for surgery within last 4 weeks.
-
MCCoDInjuryIncident —
Observation profile for external cause or poisoning details.
-
MCCoDFetalOrInfantDeath —
Observation profile for fetal or infant death details (7 components).
-
MCCoDPregnancyStatus —
Observation profile for pregnancy status at or near time of death (LOINC 82810-3).
Logical Models
-
MCCoDFrameAModel —
WHO SMART L3 logical model for Frame A. Computable data dictionary with
three-way element mappings: WHO MCCoD form → openEHR death_summary archetype
→ FHIR profile element.
-
MCCoDFrameBModel —
WHO SMART L3 logical model for Frame B. Same mapping structure as Frame A.
Extensions
Terminology
- 7 local Code Systems defined
- 6 Value Sets defined
- 13 LOINC codes referenced across profiles
-
ICD-version-agnostic cause-of-death ValueSet supporting ICD-10, ICD-10-CM,
ICD-11 MMS, and SNOMED CT with extensible binding
Examples
-
MCCoD Document Bundle Example —
Complete MCCoD document for a 45-year-old male death from acute myocardial
infarction due to coronary artery disease. ICD-10 coding (dorisDerived = false).
Demonstrates all mandatory Frame A elements and Frame B General elements.
Narrative Pages
- Background and Context
- Design Decisions (9 documented decisions with rationale)
- Frame A Specification
- Frame B Specification
- Terminology
- Conformance
- WHO SMART Guidelines Alignment
- openEHR Alignment (full element mapping table)
- Examples
Known Issues and Planned Improvements
-
Full WHO SMART L3 compliance (CRMIShareableStructureDefinition conformance,
CQL decision logic) is planned for v0.2.0
-
Full L2 DAK (BPMN workflows, DMN decision tables, indicators) is planned
for a subsequent version in collaboration with AeHIN member countries
-
A CapabilityStatement for systems implementing this IG is planned for v0.2.0
-
Country-specific extension guidance with worked national IG examples is
planned following initial member country review
-
ICD-11 XS place-of-occurrence codes in the
mccod-place-of-injury-codes ValueSet description should be
verified against the live ICD-11 browser before formal publication
-
SNOMED CT concept references in terminology cross-references are informative
and should be verified against a SNOMED CT release before formal publication